Storage
Configure energy storage systems for monitoring and optional automated control.
Storage
What Is an Energy Storage?
An energy storage is any device designed to store electrical energy.
The main role of a storage is to improve overall system efficiency by storing surplus energy and releasing it later when energy is needed.
Both standalone storage systems and storages integrated with hybrid inverters are supported, provided the Unwaste Robot can read their data and control their operating modes.
Configuration
Configuring an energy storage requires mapping Home Assistant sensors to capacity, energy counters, and optional control entities. The form is the same for all supported battery types.
Name and Description
Name is required. Description is optional.
Capacity Total
Mandatory. Defines the total capacity of the energy storage.
Available options:
Constant Energy – enter a fixed capacity value in kWh
Reading Energy – select a Home Assistant entity from which the total capacity is read, for batteries that have dynamic or configurable capacity.
Capacity Reserved
Mandatory. Defines the portion of capacity that must always remain unused to protect the storage from degradation (see Storage energy levels in Notes).
Available options:
Constant Energy – fixed reserved capacity in kWh
Constant Percent – reserved capacity as a percentage of total capacity
Reading Energy – Home Assistant entity providing reserved capacity in kWh, for batteries that have dynamic or configurable capacity.
Reading Percent – Home Assistant entity providing reserved capacity as a percentage, for batteries that have dynamic or configurable capacity.
Important: Incorrect configuration may prevent charging or discharging.
Energy Stored
Mandatory. Defines one or three Home Assistant entities (depending on storage type) used to read how much energy has been stored.
For a three-phase storage, you can provide:
one sensor for summed energy (leaving the rest empty) - it must be specified in the L1 field
three sensors, each corresponding to one phase - L1, L2, L3.
For a single-phase storage in a three-phase installation, only one field is used. It should correspond to the phase of the circuit the storage is connected to.
It is not the same as charge level. Energy stored represents the total amount of energy charged into the storage over a longer period of time (across multiple charging cycles).
Charge level is current value of energy stored in storage.
Each reading block has a Monitoring alerts button. See Monitoring alerts.
Energy Retrieved
Mandatory. Defines one or three Home Assistant entities (depending on storage type) used to read how much energy has been retrieved from the storage.
For a three-phase storage, you can provide:
one sensor for summed energy (leaving the rest empty) - it must be specified in the L1 field
three sensors, each corresponding to one phase - L1, L2, L3.
For a single-phase storage in a three-phase installation, only one field is used. It should correspond to the phase of the circuit the storage is connected to.
Energy retrieved represents the total amount of energy retrieved from the storage over a longer period of time (across multiple discharging cycles).
Power Charge
Optional. Defines one to three entities used to read the current charging power.
For a three-phase storage, you can provide:
one sensor for summed power (leaving the rest empty) - it must be specified in the L1 field
three sensors, each corresponding to one phase - L1, L2, L3.
For a single-phase storage in a three-phase installation, only one field is used. It should correspond to the phase of the circuit the storage is connected to.
Power Discharge
Optional. Defines one to three entities used to read the current discharging power.
For a three-phase storage, you can provide:
one sensor for summed power (leaving the rest empty) - it must be specified in the L1 field
three sensors, each corresponding to one phase - L1, L2, L3.
For a single-phase storage in a three-phase installation, only one field is used. It should correspond to the phase of the circuit the storage is connected to.
Charge Level
Defines the entity used to read the current charge level of the storage.
The charge level can be provided as:
"None" - no charge level reading available
"Energy" - an energy value (kWh), or
"Percent" - a percentage value
See Storage energy levels in Notes for details.
Charge level is optional, but it is needed to properly control a storage when the Unwaste Robot manages charging from the grid.
It is not always equal to total energy stored minus total energy retrieved, as all storages experience some energy loss.
Control
Enabling Control
To allow the Unwaste Robot to control a storage, control must first be enabled.
Without enabled control, the storage is only monitored and it would remain in "Unmanaged" mode.
Next, you need to select type of control:
"None" - no control available. It is like a disabled control, but not the same.
"State" - storage is controlled via setting states for each mode. Control entities must be selected, and finally values must be defined for each entity and for each supported control mode (or disabled for specific modes if required).
The selected control type determines whether the States Map section is available for configuration.
Note: "None" and "Disabled" are separate concepts and serve different purposes.
"None" means that there is no control available at all.
"Disabled" allows to temporarily disable control, without losing all the configuration stored in "State" form.
Selecting Entities
The first step is selecting which Home Assistant entities are used to control the storage.
Supported control entity types include Switch, Select, and Number entities.
Switch Entities
Switch entities accept a simple on/off (true/false) value, similar to a light switch.
Select Entities
Select entities allows choosing one value from a predefined list, for example selecting an operating mode supported by the device.
Storage Control Modes
A storage can operate in one of the following modes:
Disabled mode – the storage is temporarily disabled by user or the Unwaste Robot
Unmanaged mode – the storage is not controlled by the Unwaste Robot
Default mode – the storage follows its internal logic - used when the storage is managed, but there is no need for any action.
Force charge – the storage is instructed to charge from the grid
Force discharge – the storage is instructed to discharge to the grid
Lock discharge – the storage is told to not discharge
Lock both – the storage is told to not charge or discharge
Enable only the modes your storage hardware supports. For modes you do not use, leave them disabled in the States Map.
Selecting Values for Each Mode
Each control mode can be configured independently. For each mode we are setting a "state" - that is a collection of values for each control entity. When a mode becomes active, all enabled control entities for that mode are set simultaneously.
For each mode:
enable or disable the mode using the switch next to its name (if available)
define what value should be set to each control entity, or disable a specific entity for that mode
Note: Each state must have at least one entity enabled.
Note 2: (important) If a storage doesn't support selected mode, it applies Default mode instead.
Optional Monitoring
Optional voltage, current, power, and additional sensors are configured in the Optional monitoring section. See Optional monitoring and Additional readings.
Important Notes
Storage Energy Levels
Each storage defines two capacity values:
total capacity – the theoretical maximum energy the storage can hold
reserved capacity – the minimum energy level that must remain to protect storage health
Based on these values, the system distinguishes:
energy in storage – the raw reported energy value
available energy in storage – energy in storage minus reserved capacity
Important: If a storage device already subtracts the reserved capacity internally, configure the total capacity accordingly and set reserved capacity to zero.
Power flow
Typical case
Separate power charge and power discharge parameters are the most common way in storages to determine total power flow, as these are intuitive to configure and unambiguous. The system uses the difference between them to present total power flow of a storage on a graph.
Ambiguous devices
But there are storages that supply only one value, and what is even worse, it does not always follow the same convention of direction of power flow.
In such cases, total power flow should be entered into one of these fields (leaving second one blank), and if the direction is incorrect on the graph, then you need to swap these fields.
Single phase readings for these parameters shouldn't be mixed with three phase readings.
Screenshot (main form)

Screenshot (control / States Map)