Surplus mode
Use surplus mode to increase consumption when excess solar production is available.
This page explains how the Unwaste Robot decides when to request Surplus operating mode on managed devices.
Configuration (thresholds, required readings, States Map) is described in Connection and Device control.
Purpose
Surplus mode increases local use of photovoltaic production when the installation is exporting energy to the grid. The goal is to absorb excess solar energy with controllable loads instead of feeding it back to the grid.
Surplus is a separate control signal from price-based modes. You map what Surplus means for each device in the States Map, just like Eco or Comfort.
Where Surplus sits among operating modes
For devices, operating modes form a scale from lower to higher energy use:
Off < Eco < Comfort < Surplus < BoostSurplus sits between Comfort and Boost. It encourages more consumption than Comfort, but it is not the same as Boost — Boost is driven by favourable electricity prices, while Surplus is driven by export to the grid.
Independent from electricity prices
The decision to enter or leave Surplus mode is based on import and export measurements on the main circuit and the thresholds you configure on the connection.
Price-based control runs in parallel. The Unwaste Robot evaluates both:
the mode suggested by tariffs (Off, Eco, Comfort, or Boost), and
whether surplus conditions are currently met.
If surplus conditions are met and the price-based mode is Off, Eco, or Comfort, the device may receive Surplus instead.
If surplus conditions are met but the price-based mode is Boost, Boost wins. Boost can increase consumption beyond Surplus and may draw energy from the grid; the system treats that as the economically preferred choice when prices justify it.
When the system enters Surplus mode
Surplus entry is evaluated at the end of each 15-minute control interval.
The system looks at average export power over the previous completed 15-minute period. If that average is at or above your Surplus on threshold, surplus conditions become active for managed devices (subject to the Boost rule above).
This means entry is not instantaneous — the robot waits for a full 15-minute window of sustained export before reacting.
When the system leaves Surplus mode
While Surplus is active, exit is checked much more often — on each 5-second reading cycle.
The system tracks import energy in the current 15-minute period. If import reaches the level implied by your Surplus off threshold, Surplus ends immediately and the device returns to the current price-based mode (Off, Eco, Comfort, or Boost).
So entry is evaluated every 15 minutes, but exit can happen within seconds when import rises.
Anti-oscillation
If Surplus ends because import crossed the off threshold, the system does not re-enter Surplus in the same 15-minute period based on that export window.
This reduces rapid switching when export and import alternate quickly — for example when a load turns on and off near the threshold.
Re-entry is only considered after the next full 15-minute evaluation cycle, and only if export conditions are met again.
Energy storage and export
Surplus reacts to export at the grid connection. In practice, export usually means energy that was not used locally and was not stored in the battery.
Typical order of use for PV production:
Cover immediate consumption in the installation
Charge storage (if available and not full)
Export any remaining surplus to the grid
Surplus mode targets loads when step 3 would otherwise occur — that is, when there is a measurable export despite local consumption and storage.
What Surplus does not do
Surplus is not available in schedules or overrides — only through the default control mechanism when Surplus mode is enabled on the connection.
Surplus does not replace manufacturer safety logic or guarantee that a device will absorb a specific amount of energy.
Surplus does not control battery charging directly; storage follows its own rules (see Storage control).