Raw readings

When the system is STARTED:

  • the Unwaste Robot reads configured sensors every 5 seconds.

These readings may include, depending on configuration:

  • power sensors (W, kW),

  • energy counters (Wh / kWh),

  • state-of-charge, modes, and other device-specific values.

Aggregation blocks

To store consistent history and align with control decisions:

  • readings are aggregated into 15-minute blocks,

  • blocks are aligned to full quarters (00, 15, 30, 45 minutes).

A 15-minute block is a practical compromise:

  • small enough to reflect typical changes in production and load,

  • large enough to store efficiently and produce stable charts.

Storage rule

  • Aggregated 15-minute totals are stored in the database.

  • Power Flow "current" values are not stored.

  • Graphs and historical views rely on stored aggregation, not raw samples.

STOPPED periods

When the system is STOPPED:

  • there is no data collection,

  • and therefore no aggregation for that period.

This is why:

  • daily totals "pause" while STOPPED,

  • historical graphs show zeros for those intervals (timeline continuity),

  • and aggregated totals exclude those missing intervals.